1.10 - Imager Field Selection and Resolution
The CR2500’s dual eld optical system may be modied based on your scanning environment.
The 1.3 Million Pixel imager is divided into wide eld and high density decode zones. In each zone the resolution
is 1024 x 640 pixels (see Figure 1.26).
If only the high density eld is used (small symbols), the wide eld image can be ignored. If only the wide
eld is used (large symbols), the high density eld can be ignored. Further optimization may be obtained by
"windowing" the eld to a smaller area. BY DEFAULT, THE CR2500 DECODES ONLY THE WIDE FIELD.
SXGA Imaging Area
Figure 1.26
Wide
High
Density
1024
640
640
1.11 - Decode Zone
Figure 1.27