10/29/2014
Page 45 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Allow Code 128 Short
Margin
0: disallow short margin Code 39 symbol decoding
1: allow short margin Code 39 symbol decoding
Code 11 Decoding with one or
two checksum digits checked
Strip checksum(s) from the
result string
Note: The firmware determines whether one-digit or two-digit
checksum should be checked internally.
See Section 11.1 - Pharmacode for more details.
Reverse instead of Normal
direction
Note: The reader decodes a Pharmacode in either horizontal or
vertical orientation by default.
Valid Range: Each 8 bits can be 04 to 10 (#16)
Bit 0 – Bit 7: min bar count, 04 to 10 (#16)
Bit 9 – Bit 15: max bar count, 04 to 10 (#16)
Valid Range: F (#15) to 1FFFE (#131070)
Valid Range: F (#15) to 1FFFE (#131070)
Keep reading codes as
long as button is held
down
0: Disabled (requires button to be released before next scan occurs)
1: Enabled
Note: When enabled, register 159 should be greater than zero.